【VMware Cloud Director】Cassandraとの連携

・手順

(オプション)

CassandraにてSSL認証が有効でない場合、global.propertiesに追記

vi /opt/vmware/vcloud-director/etc/global.properties

cassandra.use.ssl = 0

cell-management-toolにてcassandraを構成

./cell-management-tool cassandra --configure --create-schema --cluster-nodes 172.16.20.40,172.16.20.41,172.16.20.42,172.16.20.43 --username vcloud --password 'VMware1!' --ttl 30 --port 9042

Verifying Cassandra settings...
Cassandra setting valid for node: 172.16.20.40
Cassandra setting valid for node: 172.16.20.41
Cassandra setting valid for node: 172.16.20.42
Cassandra setting valid for node: 172.16.20.43
Cassandra configuration settings verified successfully
vcloud_metrics keyspace created...
vm_metrics table created...
adding configured metrics to the schema...
adding counter: cpu.usage.average
adding counter: cpu.usagemhz.average
adding counter: cpu.usage.maximum
adding counter: mem.usage.average
adding counter: disk.provisioned.latest
adding counter: disk.used.latest
adding counter: disk.read.average
adding counter: disk.write.average
vapp_metrics table created...
vdc_metrics table created...
org_metrics table created...
Persisting Cassandra settings...

 Success. The monitoring service is now configured to persist data into cassandra nodes(172.16.20.40,172.16.20.41,172.16.20.42,172.16.20.43), vCD cell(s) must be restarted if they are already running.

各セルのサービス再起動

service vmware-vcd restart

・公式手順